Neutrik
Neutrik
etherFLEX® TOP CAT5e Cable Assemblies
Introducing the etherFLEX® TOP CAT5e ethernet cable assemblies expertly fitted with etherCON® TOP Connectors on each end, completed with Sealing Caps for TRU...
- Product code
- ETHERFLEX-TOP-CAT5E-CABLE-ASSEMBLIES
- Category
- Cables & Cases
Specifications
Product
- Title
- NKE5E-E1E1-*
- Product family
- etherFLEX®
- Connection type
- etherCON® TOP
Electrical
- Contact resistance
- ≤ 200 mΩ (initial) ≤ 20 mΩ (deviation to initial)
- Insulation resistance
- ≥ 0.5 MΩ @ 0.5 kVDC
- Dielectric strength
- Contact to contact: ≥ 1 kV Contacts to screen: ≥ 1.5 kV
- Rated current per contact
- ≤ 1.0 A
- Rated voltage
- ≤ 57 VDC
- Transmission performance
- CAT5e acc. to TIA/EIA 568A component specifications CAT5e acc. to ISO/IEC 11801 component specifications
- Frequency range
- 1 - 100 MHz
- Power over Ethernet
- PoE type 4 class 8 acc. IEEE 802.3bt
- Shielding
- S/UTP
Mechanical
- Lifetime
- min. 750 mating cycles
- Bending radius
- fixed laying: ≥ 28 mm flexible laying: ≥ 56 mm flexible laying with forced guidance: ≥ 105 mm
- Bending cycles
- Drag chain: ≥ 3 000 000 @ 4.5 m chaing length, 3 m/s velocity and 3 m/s² acceleration (cable but not kink protection)
- Cable Jacket
- Polyurethane (PUR)
Environmental
- Flame resistance
- V-0 acc. to UL94 (Connectors/Shell) V-2 acc. to UL94 (RJ45) Vertical flame propagation for cable acc. to IEC 60332-2-2 (Cable)
- Standard compliance
- 2011/65/EU ISO/IEC 11801-1 Ed. 1.0:2017 IEC 60603-7-3 Ed.2.0:2010 IEC 60512-99-002 Ed.2.0:2022 IEC 60512-9-3:2011 Flame resistance acc. to UL94, IEC 60332-2- Oil resistance acc. to IEC 60811-404, DIN EN 50363-10-2 Halogen free acc. to IEC 60754-1, DIN VDE 0472 part 815 PWIS acc. to PV 3.10.7 (PAINT WETTING IMPAIRMENT SUBSTANCES FREEDOM)
- Ingress protection class
- IP65 acc. to IEC 60529:1989+A1:1999+A2:2013 when sealing cap is closed IP65 & IP67 acc. to IEC 60529:1989+A1:1999+A2:2013 in mated condition with etherCON® TOP airtight
- Temperature range
- installation: -20 °C to +60 °C fixed laying: -30 °C to +80 °C flexible laying: -30 °C to +70 °C flexible laying with forced guidance: -20 °C to +60 °C