Clear-Com

Clear-Com
ARCADIA CENTRAL STATION
Arcadia Central Station Combined Wired and Wireless Intercom Keypanels with Essential feature set I.V. Direct Clear-Com Global...
- Product code
- ARCADIA-CENTRAL-STATION
- Category
- Audio
Specifications
- Delivery
- License Ticket, may include multiple licenses
- License Host
- Arcadia
- Activation
- Via CCM, Online (recommended) or Offline
- Transferable
- No, fixed to Arcadia
- Recovery
- Yes, by Clear-Com Support or Service Center
- Part number
- ARCADIA-8P-LIC, ARCADIA-16PLIC
- Capability
- Additional 8 or 16 Licensed Port Upgrade Option
- Validity
- Perpetuity. Does not expire
- Note
- Licensed Port capacity is ordered with Arcadia. ARCADIA-8P-LIC and ARCADIA-16PLIC allow upgrade of Arcadia capacity in the field.
- Headset
- 4-pin XLR-M (X4), 5-pin XLR-F (X5)
- Gooseneck Microphone
- ¼” TRS 7/16UNF-2A Threaded
- 2-Wire I/O
- (4) XLR-3F
- 4-Wire I/O
- (8) RJ45
- Audio Crossover Mode
- Software selectable; AES-72 Type 3M Pinout: 4-Wire - 1: Out, 2: In or 4-Wire -X - 1: In, 2: Out; Special use of Port #8 using provided cable
- Program In/ Stage Out
- XLR-3F, XLR-3M
- GPIO
- (2) DB9F (1 GPI, 2 GPO, 12V - each connector)
- FSII E1 TCVR/SPL Ports
- (2) RJ45, (2) SFP (RJ45 or SFP)
- FSII DECT Synchronization
- (2) RJ45 (Input and Output)
- LAN
- (2) RJ45, (2) SFP (Function assignable)
- AC Power Connector
- IEC-C14
- DC Power Connector
- KPJX-4S-S
- Grounding Screw
- Terminal
- Note
- While mechanically identical, SFPs are designed with different properties for data rates, power and fiber cable type. Please refer to the Clear-Com SFP Compatibility Chart for compatible SFP transceivers.
- Input Type
- Dynamic/Electret - Selectable
- Headset Mic Voltage
- 5V
- Input Level (nominal)
- -45dBu
- Input Level (max)
- -10dBu
- Frequency Response
- 200Hz to 12kHz ±3dB
- Mic Limiter Threshold
- -35dBu ±3dB
- Mic Limiter Range
- ≥ 20dB
- Speaker
- 1.6 x 2.8”
- Load
- 4Ω
- Max Speaker Level
- 87dB ± 2dB SPL A at 3ft/1m
- Frequency Response
- 100Hz – 10kHz
- Max Output Level before 1% Distortion
- 18dBu ± 2dB
- Total Harmonic Distortion (THD)
- < 0.5% THD at 1kHz
- Nominal Level
- 0dBu (adjustable -12dB to +12dB)
- Maximum Level
- +18dBu
- Frequency Response
- 80Hz to 20kHz ±3dB
- Impedance
- >= 10KΩ
- Impedance
- 200Ω + 10%
- Compatibility
- Clear-Com, RTS-TW with Call and Remote Mic Kill
- Termination
- Optional per pair (A/B or C/D)
- Nulling
- User initiated Auto-Calibration
- Null Depth
- >60dB at 1kHz
- Nominal Level
- -18dBu (CC), -12dBu (RTS-TW)
- Headroom
- 18dB
- Frequency Response
- 200Hz to 12kHz. ±3dB
- Impedance
- >= 10KΩ bridging
- Total Harmonic Distortion (THD)
- < 0.1% THD @ 1 kHz
- Power
- 560mA optional per pair (A/B or C/D)
- Voltage
- 25-28V DC
- Headset Mic
- 200Hz to 12kHz
- Gooseneck Mic
- 200Hz to 12kHz
- Speaker
- 100Hz to 10kHz
- FreeSpeak Edge
- 200Hz to 12kHz
- FreeSpeak II
- 200Hz to 7.1kHz
- HelixNet
- 200Hz to 10kHz
- I.V. Direct
- 50Hz to 7.1kHz
- Dante
- 20Hz to 20kHz
- 4-Wire
- 80Hz to 20kHz
- 2-Wire
- 200Hz to 12kHz
- Output Voltage
- 12V, separate pin
- Current (Max)
- 2mA
- Input
- 2
- Style
- Optically isolated
- Input Voltage Range
- 4 - 30V DC or AC
- Input Current
- >=1.2mA required
- Outputs
- 4
- Style
- SPDT / Power Relay
- Normalized
- Open or Closed, separate pins
- Switching Voltage (Max)
- 30V DC
- Switching Current (Max)
- 1A
- Input Frequency Range
- 100 - 240V AC
- Input Frequency Range
- 50 - 60Hz
- Input Power (Max)
- 160W
- BTU (Max)
- 545BTU/h
- Input Power Connector
- IEC-C14
- Voltage
- 12V DC ± 5%
- Current (Max)
- 12A
- Power (Max)
- 144W
- BTU (Max)
- 491BTU/hr
- Input Power Connector
- KPJX-4S-S
- Type
- PSU-EXT-001 (supplied)
- Mounting Bracket
- 272G048 (optional)
- Input Voltage Range
- 100 - 240V AC
- Output Voltage
- 12V DC ± 5%
- Output Current (Max)
- 12.5A
- Output Power (Max)
- 150W
- Output Power Connector
- KPPX-4-P
- Operating
- 32° to 113°F (0° to 45°C)
- Storage
- -22° to 158°F (-30° to 70°C)
- Humidity
- 20-90% Non-Condensing
Documents
- ManualArcadia Central Station User Guide
- ManualArcadia Central Station User Guide
- ManualArcadia HelixNet User Guide
- ManualSFP Compatibility Chart
- DatasheetArcadia Central Station Datasheet
- DatasheetCCM for Arcadia and Edge Datasheet
- Quick startArcadia Central Station Quick Start Guide
- Quick startHelixNet User Station Installation Quick Start Guide
- DocumentArcadia & FreeSpeak Edge Base Station IP Network Guide
- DocumentChoosing the Right Wired Headset for Intercom
Documents are hosted by the manufacturer; these are links to their files.