Artistic License
Artistic Licence railSafe

Artistic License

Artistic Licence railSafe

railSafe is a bidirectional DMX512/RDM isolator, signal booster and surge protection device, with a ‘data fixer’ for dodgy DMX. The product provides self-healing electrocution protection on the DMX512 ports and surge protection on all terminals. This protects connected equipment against lightning strikes. The surge protection is sacrificial, but the product reports spent protection with a front panel indicator and via the fault tally output. Crucially, when protection is spent, it shorts the DMX terminals, continuing to protect the DMX512 output. railSplit uno is powered from a 9 to 48 VDC power source. We recommend the PSU-24-0.75-FER.

Product code
RAILSAFE
Category
Lighting

Specifications

Learn more

In fix mode, the product discards all RDM and other specialist data packets. It also adjusts the DMX timing to values that are likely to be acceptable to fixtures that do not fully comply with the DMX standard.
The list below shows the fix mode features.
Automatic timing correction for DMX512.
Accepts breaks from 56µS to 1000µS
Accepts MaB from 5µS to 1000µS
Accepts MbB from 0µS to 1000µS
Accepts channel count from 1-512
Accepts refresh from 23mS to 1000mS
Filters out consecutive breaks
Re-times bytes with 1 stop bit to 2 stop bits
Generates DMX with fixed timing parameters: Refresh = 33Hz, Brk=250µS, MaB=30µS, P=30mS, C=512, MbB=30µS
Filters out all Non-Zero Start Codes

Features

Input optical isolation
Bi-directional output (RDM supported)
Optimized for electrically noisy environments
Mains electrocution protection (self-healing) on DMX512 input and output
Surge protection (sacrificial) on all terminals
Front panel fault indication
Fault report tally output for BMS integration
Surface mount or DIN rail mounted
DMX-Fix mode to handle compatibility issues

Specification

Listing
UKCA, CE, WEEE, RoHS
IP Rating
IP20 indoor use only
Input power (max)
1.5 W
Input Voltage
9 to 48VDC
Width
36 mm
Height
90 mm
Depth
32 mm
Net Mass
0.10 kg
Connection
Screw terminal
Electrocution protection
Input, Loop and all outputs protected against continuous connection to 425 VAC (self-healing)
Surge protection (Input, Loop and all outputs):
Max IDC 30,000A (8/20µS) sacrificial (1 operation)
Max IDC 20,000A (8/20µS) sacrificial (10 operations)
Max IDC 20A (10/1000µS) sacrificial (1500 operations)
Manufacturer
Artistic Licence
Country of Manufacture
UK